Automation & Vision Systems
Positional accuracy | < ±0.15 mm (sensor-dependent) |
Nominal width | 800 to 4000 mm |
Transfer length | 600 to 2500 mm |
Nominal actuating travel | |
LÜ 600 to 700 mm | max. ±25 mm |
LÜ 800 to 1300 mm | max. ±50 mm |
LÜ 800 to 2500 mm | max. ±80 mm |
Nominal actuating speed at outfeed roller | 1 to 30 mm/s (AG 93 with F=3000 N) |
Web tension | Max. 2000 N (reinforced version up to 3000 N, optionally up to 20,000 N) |
Roller diameter | 100/120/160/200 mm |
Ambient temperature | +10°C to +50°C |
Relative humidity | 15 to 95 % (non-condensing) |
Operating voltage | |
Nominal value | 24 V DC |
Nominal range | 20 to 30 V DC (ripple included) |
Nominal range with power supply | 100 to 240 V, 50/60 Hz |
Current consumption | max. 7,7 A DC |
Interface | Ethernet UDP/IP, EtherNet/IP |
optional: Profinet and other databus systems | |
Protection rating | IP 54 |